Description

Device used at outlets to convert concentrated flow to sheet flow, preventing erosion of the receiving area. Tops of channels, earthen berms, or rigid weir-like structures may function as level spreaders.

Applications

  • Flat or gentle sloping areas.
  • Outlets for dikes and diversions.
  • Where concentrated flows are discharged.

Installation and Implementation Requirements

  • Construct on undisturbed soil.
  • Do not construct on fill material.
  • Locate where reconcentration of water will not occur.
  • A stabilized and well vegetated slope of less than 10% shall be located below the level spreader.
  • Filter runoff containing high sediment loads through a sediment-trapping device prior to release to the level spreader.
  • Incorporate a rigid outlet lip design for high discharge flows.
  • 0% grade on the spreader lip is necessary for uniform sheet flow.
  • Avoid operating vehicles and heavy equipment on the level spreader to maintain a smooth level surface for the overflow weir.

Considerations

  • Not applicable to sediment-laden runoff.
  • The level spreader lip needs to be at a 0% grade to confirm no erosion or concentration of flows occur.
  • Not recognized as a pollutant reduction BMP when by itself, but is necessary for other BMP devices to function properly. It will also remove some pollutants due to some suspended sediment that settles out.
  • Storm water approaching the BMP should not be high energy.

What to Inspect

  • Is there accumulated debris or sediment in the level spreader?
  • Does the level spreader have a slope of 0% along the spreader lip?
  • Is there evidence of erosion, channelization, or concentrated flow at the discharge area?
  • Are there low spots in spreader?

Maintenance

  • Keep level spreader at 0% grade. 
  • Remove any accumulated debris and sediment and properly dispose off-site.
  • Mow grass to assure the level spreader is properly functioning.